Basic data | |||||||
---|---|---|---|---|---|---|---|
Series | MLD 500 | ||||||
Device type | Transmitter | ||||||
Functions | |||||||
Functions | Range reduction | ||||||
Characteristic parameters | |||||||
Type | 4, IEC/EN 61496 | ||||||
SIL | 3, IEC 61508 | ||||||
SILCL | 3, IEC/EN 62061 | ||||||
MTTFd | 204 years, EN ISO 13849-1 | ||||||
Mission time | 20 years, EN ISO 13849-1 | ||||||
Protective field data | |||||||
Operating range | 0.5 ... 50 m | ||||||
Optical data | |||||||
Number of beams | 3 Piece(s) | ||||||
Beam spacing | 400 mm | ||||||
Light source | LED, Infrared | ||||||
LED light wavelength | 850 nm | ||||||
Transmitted-signal shape | Pulsed | ||||||
LED group | Exempt group in acc. with EN 62471:2008 | ||||||
Electrical data | |||||||
Performance data | |||||||
Supply voltage UB | 26.5 ... 31.6 V | ||||||
Current consumption from AS-i circuit | 50 mA | ||||||
Interface | |||||||
Type | AS-Interface Safety at Work | ||||||
AS-i | |||||||
Function | Process | ||||||
AS-i profile | S-7.B.1 | ||||||
Slave address | 1..31 programmable, default=0 | ||||||
Cycle time acc. to AS-i specifications | Max. 5 ms | ||||||
Type | AS-Interface Safety at Work | ||||||
Connection | |||||||
Number of connections | 1 Piece(s) | ||||||
Connection 1 | |||||||
Type of connection | Connector | ||||||
Function | Machine interface | ||||||
Thread size | M12 | ||||||
Material | Metal | ||||||
No. of pins | 5 -pin | ||||||
Number of connections | 1 Piece(s) | ||||||
Mechanical data | |||||||
Dimension (W x H x L) | 52 mm x 900 mm x 64.7 mm | ||||||
Housing material | Metal, Aluminum | ||||||
Lens cover material | Plastic / PMMA | ||||||
Material of end caps | Diecast zinc | ||||||
Net weight | 2,000 g | ||||||
Housing color | Yellow, RAL 1021 | ||||||
Type of fastening | Swivel mount, Groove mounting | ||||||
Operation and display | |||||||
Type of display | LED | ||||||
Number of LEDs | 3 Piece(s) | ||||||
Environmental data | |||||||
Ambient temperature, operation | -30 ... 55 °C | ||||||